2013年11月28日星期四

configuration S5300 file, and patch files

ftp> binary
200 Type set to I.
ftp> get S5328C-SI  -V200R002C00SPC100.cc
200 Port command okay.                                                   
150 Opening BINARY mode data connection for file transfer.                     
226 Transfer complete.

ftp: 12472284 bytes received in 80.33Seconds 1350.65Kbytes/sec.
The preceding output indicates the configuration file has been transferred and you can find it in D:\>.
ftp> get vrpcfg.zip
200 Port command okay.                                                   
150 Opening BINARY mode data connection for file transfer.                     
226 Transfer complete.
ftp: 589 bytes received in 0.01Seconds 60Kbytes/sec.
The preceding output indicates the configuration file has been transferred and you can find it in D:\>.
ftp> get S5324TP-SI   sph001.pat
200 Port command okay.                                                   
150 Opening BINARY mode data connection for file transfer.                     
226 Transfer complete.
ftp: 333436 bytes received in 0.33Seconds 1350.65Kbytes/sec.

The preceding output indicates the configuration file has been transferred and you can find it in D:\>.

2013年11月25日星期一

Use the S5300 as the TFTP Client

Directory of flash:/

  Idx  Attr     Size(Byte)  Date        Time(LMT)      FileName
    0  -rw-     12,472,284  Nov 04 2010 19:43:18   S5352C-EI-V200R002C00SPC100.cc

30,008 KB total (16,544 KB free)
<Quidway> dir *.zip
Directory of flash:/

  Idx  Attr     Size(Byte)  Date        Time(LMT)      FileName
    0  -rw-            589  Nov 04 2010 20:55:54    vrpcfg.zip

30,008 KB total (16,544 KB free)
<Quidway> dir *.pat
Directory of flash:/

  Idx  Attr     Size(Byte)  Date        Time(LMT)       FileName
    0  -rw-        333,436  Jan 29 2010 16:54:40    s5300sph001.pat

30,008 KB total (16,544 KB free)
Run the following commands on the S5300 to back up the data. The backup system software is S5300-V200R002C00SPC100-bak.cc, the backup configuration file is vrpcfg-bak.zip, and the patch file is s5300sph001-bak.pat.
<Quidway> tftp 10.164.30.29 put S5300-V200R002C00SPC100.cc  S5300-V200R002C00SPC100-bak.cc
Info: Transfer file in binary mode.                                            
Uploading the file to the remote TFTP server. Please wait...|                  
TFTP: Uploading the file successfully.                                         
12472284 bytes send in 160 seconds.
<Quidway> tftp 10.164.30.29 put vrpcfg.zip vrpcfg-bak.zip
Info: Transfer file in binary mode.
  Uploading the file to the remote TFTP server. Please wait.../
  TFTP: Uploading the file successfully. 
  589 bytes send in 0.01 second.
<Quidway> tftp 10.164.30.29 put s5300sph001.pat s5300sph001-bak.pat                                                            
Info: Transfer file in binary mode.                                            
Uploading the file to the remote TFTP server. Please wait...\                  
TFTP: Uploading the file successfully.                                          
  333436 bytes send in 1 second.
3.    Obtain the system software of the target version from the server.
<Quidway> tftp 10.164.30.29 get S5300EI-V200R003C00SPC300.cc
Info: Transfer file in binary mode.
  Downloading the file from the remote TFTP server. Please wait.../
TFTP: Downloading the file successfully.
14,066,348 bytes received in 109 seconds
If the message "Downloading the file successfully" is displayed, the system software has been downloaded.
4.    (Optional) Obtain the new configuration file from the server.
If the configuration file does not need to be changed after the upgrade, this step is not required.
<Quidway> tftp 10.164.30.29 get vrpcfgnew.zip                        
Info: Transfer file in binary mode.                                             
Downloading the file from the remote TFTP server. Please wait.../              
TFTP: Downloading the file successfully.                                       
    2757 bytes received in 1 second.
5.    Specify the system software in service, which is loaded when the S5300 is started.
<Quidway> startup system-software S5300EI-V200R003C00SPC300.cc

If the following information is displayed after you run the startup system-software file command, enter Y to update the BootROM. If the BootROM is upgraded successfully, go to step 7; otherwise, go to step 6. When you upgrade a stack of V100R003, you must manually upgrade the BootROM according to step 6.
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
BOOTROM begin to be upgraded ! please wait for a moment...,

Info: BOOTROM upgrade is ok.
Succeeded in setting the software for booting system.
6.    (Optional) Upgrade the BootROM in service, which is loaded when the S5300 is started.
<Quidway> system-view
[Quidway] upgrade basic-bootrom S5300EI-V200R003C00SPC300.cc
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
Upgrading BOOTROM,please wait for a moment...,

[Slot 0]:
Info: BOOTROM upgrade is ok.
Succeeded in setting the software for booting system.

In V100R003 or a later version, the BootROM is upgraded automatically. To upgrade the software to other versions, you must upgrade the BootROM manually. For details about automatic BootROM upgrade, see Step 5. In the case of a version rollback, you are advised to manually upgrade the BootROM to prevent a rollback failure.
7.    Restart the S5300.

After the software is upgraded to V200R003C00SPC300, you must specify the system software for next startup. If the system software is not specified or the invalid software is specified, the device will fail to restart. For details about specifying the system software for next startup, see Step 5.
When the system asks you whether to save the configuration, enter y or n. After the setting is complete, enter y to restart the system.
<Quidway> reboot
Info: The system is now comparing the configuration, please wait.              
Warning: The configuration has been modified, and it will be saved to the next s
tartup saved-configuration file flash:/103_xu.cfg. Continue? [Y/N]:y            
Now saving the current configuration to the slot 0..                           
Save the configuration successfully.                                           
Info: If want to reboot with saving diagnostic information, input 'N' and then e
xecute 'reboot save diagnostic-information'.                                   
System will reboot! Continue?[Y/N]:y                                           
Info: System is rebooting, please wait...


Quidway S5328C-EI series switches which are new generation Ethernet gigabit switches that meet the requirements for high-bandwidth access and Ethernet multi-service convergence, providing powerful Ethernet functions for operators and enterprise customers.

2013年11月20日星期三

LS-S2318TP-EI-DC VS LS-S2318TP-SI-AC, The Difference

What are the difference of LS-S2318TP-EI-DC and LS-S2318TP-SI-AC?

Huawei LS-S2318TP-EI-DC: Huawei Quidway Switch S2300, S2318TP-EI Mainframe(16 10/100 BASE-T ports and 2 Combo GE(10/100/1000 BASE-T+100/1000 Base-X) ports and DC -48V)

Huawei LS-S2318TP-SI-AC: Huawei Quidway Switch S2300, S2318TP-SI Mainframe(16 10/100 BASE-T ports and 2 Combo GE(10/100/1000 BASE-T+100/1000 Base-X) ports and AC 110/220V)

The Quidway S2300 series switches are new generation Ethernet intelligent access switches. The S2300 is mainly deployed on the IP MAN and intranets, meeting requirements of carrying various Ethernet services and accessing the Ethernet. Based on the new generation high-performance hardware and Huawei Versatile Routing Platform (VRP), the S2300 supports rich and flexible service features and thus improves the operability, manageability, and service expansibility. In addition, the S2300 supports powerful lightning protection, security features, ACLs, QinQ, 1:1 VLAN switching, and N:1 VLAN switching to flexibly deploy VLANs.

The difference on the price:
According to our research, www.huanetwork.com is a great wholesell supplier for huawei switch, and the best price form.
LS-S2318TP-EI-DC price : $239.00
LS-S2318TP-SI-AC price : $195.00


Request a quote for them by emailing us at sales@huanetwork.com or pick up the phone and speak to one of our friendly and helpful sales reps at +852-30501940 (Hong Kong).

2013年11月19日星期二

GPON standard change

Trouble Ticket No./CR No.Huawei GPON Original requirement
Change If the OLT is connected to a Huawei ONT whose OMCI version is 0xa0 or later and the ONT reports the proprietary entity 0xff93 to the OLT, multicast configuration is issued to the ONT using the standard protocol.
Reason for Change Before the standard change, the ONT whose OMCI version is 0xa0 or later supports the multicast proprietary protocol; after the standard change, such ONTs support the standard protocol.
Impact Upgrades and services are not affected.
Original requirement If the OLT is connected to a Huawei ONT whose OMCI version is 0xa0 or later, the ID of the MAC bridge service profile instance created in single-bridge mode is changed from 0 to 1. The interoperability specification defines that in the scenario with variable-length OMCI messages, the ID of the MAC bridge service profile instance created in single-bridge mode is 1. Services are not affected.
Original requirement When the board that does not support variable-length OMCI messages is replaced with the board that supports variable-length OMCI messages, and the interconnected ONT is of OMCI version 0xB0 or later, the board issues variable-length OMCI messages to the ONT. The G.988 variable-length OMCI messages are supported.ONT configuration, upgrades, or services are not affected.

Terminals that are not listed in the attachment above may not match the specific OLT version. If such a terminal is used, confirm with Huawei technical support personnel first


For more Huawei HG8240 information please click here

2013年11月14日星期四

How to Setting Up an Environment for the Upgrade on huawei S3300 switch

In the BootROM S3352P menu or the command line view, you can use the Trivial File Transfer Protocol (TFTP) or File Transfer Protocol (FTP) to download the system software, and set it as the next startup system software. Then restart the device to complete the upgrade.
The general requirements for setting up an environment for upgrading the system using TFTP or FTP are as follows:
    You can log in to the switch from a PC through the serial interface or Telnet.
    The server and the switch can communicate with each other.
    Files for the upgrade are stored in the server.

You can upgrade the basic and advanced BootROM software using Xmodem in the basic BootROM menu; you can upgrade the system software using Xmodem in the BootROM menu.
The general requirements for setting up an environment for upgrading the system using Xmodem are as follows:
    The RS-232 serial interface on the PC and the console interface on the switch are connected through a console cable.

    Files for the upgrade are stored on the PC.

For more Huawei  information please click here
http://www.huanetwork.com/huawei-ls-s5324tp-si-ac-price_p510.html

2013年11月11日星期一

How to configure the MTU of an Ethernet Interface on Huawei NE40E Router?

Huawei NE40E Quidway NetEngine40E is based on a 400G platform, which is designed to save energy. Each slot has a forwarding capacity of 400Gbps, and the bandwidth of each slot can be smoothly expanded from 40Gbps to 400Gbps, satisfying the bandwidth demands of the next three to five years. The NE40E is compact in design and the interface density can reach 160 x 10G for a single NE40E and 240 x 10G for a single cabinet, which greatly saves space. Huanetwork.com ships Huawei NE40E router to worldwide.

Step 1:
system-view
The system view is displayed.
Step 2:
interface { ethernet | gigabitethernet } interface-number
The Ethernet interface view is displayed.
Step 3:
mtu mtu
TheIPv4 MTU of the Ethernet interface is configured.
Step 4:
system-view
The system view is displayed.
Step 5:
interface { ethernet | gigabitethernet } interface-number
The Ethernet interface view is displayed.
Step 6:
ipv6 enable
The IPv6 is enabled in this interface.
Step 7:
ipv6 mtu mtu
The IPv6 MTU of the Ethernet interface is configured.


For more Huawei information please click here

http://www.huanetwork.com/gpon-epon-terminal-price_c42

How to configure a DNS Test Instance on Huawei LS-S5348TP-SI-AC switch?

Huawei Quidway Switch S5300, LS-S5348TP-SI-AC Mainframe(44 10/100/1000Base-T ports and 4 gigabit Combo ports,AC 110/220V)

Step 1:
system-view
The system view is displayed.
Step 2:
dns resolve
Dynamic DNS resolution is enabled.
Step 3:
nqa test-instance admin-name test-name
An NQA test instance is created, and the NQA view is displayed.
Step 4:
test-type dns
The test type is set to DNS.
Step 5:
destination-address url urlstring
The name of the destination host is configured.
Step 6:
description string
A description is configured for the test instance.
Step 7:
frequency interval
The test period is set for the NQA test instance.
Step 8:
timeout time
The timeout period of a probe is set for the NQA test instance.
Step 9:
records history number
The maximum number of historical records is set for the NQA test instance.
Step 10:
records result number
The maximum number of result records is set for the NQA test instance.
Step 11:
agetime hh:mm:ss
The aging time is set for the NQA test instance.
Step 12:
dns-server ipv4 ip-address
The DNS server address is configured.


For more Huawei ME60-X3 information please click here

2013年11月7日星期四

How to configure a Recording Scheme on Huawei LS-S3328TP-EI-24S-DC switch?

LS-S3328TP-EI-24S-DC,Huawei Quidway Switch S3300, S3328TP-EI Mainframe(24 100 BASE-X ports and 2 Combo GE(10/100/1000 BASE-T+100/1000 BASE-X) ports and 2 SFP GE (1000 BASE-X) ports (SFP Req.) and DC -48V)

Step 1:
system-view
The system view is displayed.
Step 2:
hwtacacs-server template template-name
The HWTACACS server template is created.
Step 3:
aaa
The AAA view is displayed.
Step 4:
recording-scheme recording-scheme-name
A recording scheme is created and the recording scheme view is displayed.
Step 5:
recording-mode hwtacacs template-name
An HWTACACS server template that is associated with the recording scheme is configured.
Step 6:
quit
Return to the AAA view.
Step 7:
cmd recording-scheme recording-scheme-name
The commands that are used on the S3700 are recorded.
Step 8:
outbound recording-scheme recording-scheme-name
The information about connections is recorded.
Step 9:
system recording-scheme recording-scheme-name
System events are recorded.


For more Huawei MA5600 information please click here

2013年11月4日星期一

How to configure Remote Port Mirroring on Huawei S3328TP-SI Switch?

Huawei Quidway Switch S3300, S3328TP-SI Mainframe(24 10/100 BASE-T ports and 2 Combo GE(10/100/1000 BASE-T+100/1000 Base-X) ports and 2 SFP GE (1000 BASE-X) ports (SFP Req.) and AC 110/220V)

Step 1:
system-view
The system view is displayed.
Step 2:
vlan vlan-id
An RSPAN VLAN is created and the RSPAN VLAN view is displayed.
Step 3:
mac-address learning disable
The MAC address learning is disabled.
Step 4:
quit
Return to the system view.
Step 5:
observe-port index interface interface-type interface-number [ vlan vlan-id ]
An observing port is configured, and the RSPAN VLAN is specified.
Step 6:
vlan vlan-id
The RSPAN VLAN view is displayed.
Step 7:
mirroring to observe-port index inbound
Remote VLAN mirroring is configured.


For more Huawei S5328C-SI information please click here

How to configure the Peer Mode on Huawei S2309TP Switch?

Huawei Quidway Switch S2300, S2309TP-EI Mainframe(8 10/100 BASE-T ports and 1 Combo GE(10/100/1000 BASE-T+100/1000 Base-X) ports and DC -48V

The Quidway S2300 series switches are new generation Ethernet intelligent access switches. The S2300 is mainly deployed on the IP MAN and intranets, meeting requirements of carrying various Ethernet services and accessing the Ethernet. Based on the new generation high-performance hardware and Huawei Versatile Routing Platform (VRP), the S2300 supports rich and flexible service features and thus improves the operability, manageability, and service expansibility. In addition, the S2300 supports powerful lightning protection, security features, ACLs, QinQ, 1:1 VLAN switching, and N:1 VLAN switching to flexibly deploy VLANs

Step 1:
system-view
The system view is displayed.
Step 2:
ifindex constant
The constant interface index feature is enabled.
Step 3:
set constant-ifindex max-number number
The maximum number of interfaces indexed by fixed numbers is set.
Step 4:
set constant-ifindex subinterface { dense-mode | sparse-mode }
The memory distribution mode for the sub-interface index is set.


For more Huawei ls-s2309tp-ei-ac information please click here